BeyoDesalt™ Desalting Columns

Beyotime's G-25 series of desalting columns (BeyoDesalt™ G-25 Spin Desalting Column, BeyoDesalt™ G-25 Mini Desalting Column, BeyoDesalt™ G-25 Midi Desalting Column, BeyoDesalt™ G-25 Max Desalting Column) are pre-packed ready-to-use chromatography columns for simple and quick separation of high molecular weight substances from low molecular weight substances. The main application is removing salt ions, detergents, small molecule dyes, buffer agents, and other impurities from samples such as proteins, nucleic acids, peptides, and polysaccharides, which requires only one benchtop centrifuge.

Working Principle

Figure 1. Schematic diagram of the working principle of BeyoDesalt™ Desalting Columns

Product Features
Wide Application:
① Removal of phenol red from the culture medium to facilitate subsequent purification of proteins or nucleic acids by ion exchange chromatography;
② Removal of single nucleotides from DNA samples to facilitate subsequent DNA sequencing; removal of small molecular weight markers from samples; and termination of reactions between large and small molecular weight substances by separation of the two;
③ Removal of protease products, cofactors, or inhibitors;
④ Removal of excess radiolabeling in nucleic acid labeling reactions;
⑤ Removal of excess D-Biotin from in vitro biotin labeling reactions;
Significantly superior to traditional semi-permeable membrane dialysis method
① Fast separation speed, time-saving: The desalting column can quickly separate samples, typically taking only 5 minutes to process one sample, while semi-permeable membrane dialysis typically takes at least 6 hours.
② Suitable for small volume operations, high sample recovery rate: The desalting column can effectively handle small volume samples of 0.1-0.3ml, with a recovery rate usually exceeding 90%. In contrast, during the release of samples after semi-permeable membrane dialysis, some samples may adhere to the membrane and cannot be fully recovered, making it unsuitable for small volume samples.
③ Saves solution: Semi-permeable membrane dialysis requires a large amount of buffer, while this desalting column only requires 10ml of buffer to complete the experiment.
Two using methods: gravity flow & centrifugation
① Gravity flow: The sample flows through the desalting column by gravity, which is simple to operate, with a slightly higher sample recovery rate compared to centrifugation, but the sample will be diluted by approximately 1.4 times.
② Centrifugation: The sample flows through the desalting column under centrifugal force, with a slightly lower sample recovery rate compared to gravity flow, but the sample will not be diluted.

Figure 2. Schematic diagram for using Beyotime BeyoDesalt™ G-25 Spin desalting column (P2613)

Figure 3. Schematic diagram showing the two methods of using BeyoDesalt™ G-25 Mini/Midi/Max desalting column (P2615/P2617/P2619)

Typical Figures

Figure 4. The effect of Beyotime BeyoDesalt™ G-25 Mini desalting column (P2615) using gravity to separate high molecular weight substances from low molecular weight substances.

Figure 5. Effect of Beyotime BeyoDesalt™ G-25 Midi desalting column (P2617).

Figure 6. Effect of Beyotime BeyoDesalt™ G-25 Max desalting column (P2619).

Selection Guide

Beyotime offers many desalting columns. For comparison and selection, please refer to the table below.

Product Name BeyoDesalt™
Classification Multi Spin (96 well) Spin Mini Midi Max Superfine Fine
Diagram
Matrix Beyodex™
G-25 M
Beyorose™ 6FF
G-25 M
6FF
G-10
G-25 M
6FF
G-10
G-25 M
6FF
G-25 M
6FF
G-25 SF
6FF
G-25 F
6FF
Resolution ★★★ ★★★★★ ★★★★
Spin*** Sample volume 70-130μl 0.2-0.5ml 0.75-1.5ml 1.75-2.5ml Not Applicable
Elution volume 70-130μl 0.2-0.5ml 0.75-1.5ml 1.75-2.5ml
Dilution factor 1
Gravity Sample volume Not Applicable 0.1-0.3ml*
0.1-0.5ml**
0.4-1ml*
0.5-1.5ml**
1-2.5ml
Elution volume 1ml 2ml 3.5ml
Dilution factor 2-10 1.3-3 1.5-3.5
Syringe Sample volume Not Applicable Not Applicable 0.25-1.5ml Not Applicable
Elution volume 1-2ml
Dilution factor 1.3-4
AKTA
System
Sample volume Not Applicable Not Applicable 0.25-1.5ml 2-20ml
Elution volume 1-2ml 10-30ml
Dilution factor 1.3-4 1.5-5
Number of columns
used in series
Not Applicable 1-5 columns

Beyotime offers desalting columns with three types of matrix. For comparison and selection based on the molecular weight cut-off (MWCO), please refer to the table below.

Matrix MCWO Catalog Number
Multi Spin Spin Mini Midi Max Superfine Fine
Beyodex™ G-10 >0.7kDa / / P2605 P2607 / / /
Beyodex™ G-25 >5kDa P2611 P2613 P2615 P2617 P2619 P2621 P2623
Beyorose™ 6FF >400kDa P2625 P2627 P2629 P2631 P2633 P2635 P2637

The comparison and selection of BeyoDesalt™ G-25 desalting columns can be found in the table below.

Serial Name BeyoDesalt™ G-25
Classification Multi Spin
(96 well)
Spin Mini Midi Max Superfine Fine
Cat. No. P2611 P2613 P2615 P2617 P2619 P2621 P2623
Beads size 70-250μm 40-70μm 40-140μm
Volume of resin 500μl 500μl 2.1ml 5.3ml 8.3ml 5ml 70ml
Packed bed dimensions / / 0.9´6.3cm 1.3´6.6cm 1.6´8.3cm 1.6´2.5cm 2.6´18cm
Column volume 800μl 800μl 5ml 8.5ml 13.5ml 5ml 70ml
Maximum sample volume 130μl 130μl 0.5ml 1.5ml 2.5ml 1.5ml 20ml
Recovery 70-90% 70-90% 70-95% 70-95% 70-95% 95% 95%
Desalting capacity >85% >90% >95%
Plate/column material polypropylene
Storage solution 20% ethanol
Storage temperature 4-30℃